Picture PDF Manufacturer Part Number Description Avail. Price UM Qty Add
CUH AE16ANS0AC C-H AE16ANS0AC SIZE A STARTER NON REVERSING TYPE; IEC A SIZE; 7 AMPERE (UL), 20 AMPERE (IEC THERMAL CURRENT) CURRENT RATING; OPEN, DIN RAIL MOUNT ENCLOSURE TYPE; IEC CONSTRUCTION STANDARD; 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE; 1NO RIGHT MOUNT AUXILIARY CONTACT; 1.1 KW AT 220 V 3 PHASE, 2.2 KW AT 380/415/440 V 3 PHASE, 4 KW AT 500/550 V 3 PHASE, 1.5 KW AT 660 V 3 PHASE, 1/4 HP AT 115 V 1 PHASE, 1/2 HP AT 230 V 1 PHASE, 1-1/2 HP AT 208/240 V 3 PHASE, 3 HP AT 480 V 3 PHASE, 5 HP AT 600 V 3 PHASE POWER RATING/VOLTAGE; BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS; 1/3 PHASE; APPROVAL UL, CSA; NUMBER OF POLE 3; AE16 MODEL 0 $448.90 E
CUH AE16BNS0AC C-H 16BNS0AC SIZE B STARTER NON REVERSING TYPE; IEC B SIZE; 10 AMPERE (UL), 20 AMPERE (IEC THERMAL CURRENT) CURRENT RATING; OPEN, DIN RAIL MOUNT ENCLOSURE TYPE; IEC CONSTRUCTION STANDARD; 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE; 1NO RIGHT MOUNT AUXILIARY CONTACT; 1.5 KW AT 220 V 3 PHASE, 4 KW AT 380/415/440 V 3 PHASE, 5.5 KW AT 500/550 V 3 PHASE, 2.2 KW AT 660 V 3 PHASE, 1/2 HP AT 115 V 1 PHASE, 1 HP AT 230 V 1 PHASE, 2 HP AT 208/240 V 3 PHASE, 5 HP AT 480 V 3 PHASE, 7-1/2 HP AT 600 V 3 PHASE POWER RATING/VOLTAGE; BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS; 1/3 PHASE; APPROVAL UL, CSA; NUMBER OF POLE 3; AE16 MODEL 0 $457.95 E
CUH AE16CNS0AC C-H AE16CNS0AC SIZE C STARTER NON REVERSING TYPE; IEC C SIZE; 12 AMPERE (UL), 20 AMPERE (IEC THERMAL CURRENT) CURRENT RATING; OPEN, DIN RAIL MOUNT ENCLOSURE TYPE; IEC CONSTRUCTION STANDARD; 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE; 1NO RIGHT MOUNT AUXILIARY CONTACT; 2.2 KW AT 220 V 3 PHASE, 5.5 KW AT 380/415/440 V 3 PHASE, 7.5 KW AT 500/550 V 3 PHASE, 4 KW AT 660 V 3 PHASE, 1/2 HP AT 115 V 1 PHASE, 2 HP AT 230 V 1 PHASE, 3 HP AT 208/240 V 3 PHASE, 7-1/2 HP AT 480 V 3 PHASE, 10 HP AT 600 V 3 PHASE POWER RATING/VOLTAGE; BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS; 1/3 PHASE; APPROVAL UL, CSA; NUMBER OF POLE 3; AE16 MODEL 0 $524.54 E
CUH AE16DNS0AC C-H AE16DNS0AC FRDM STR-IEC OP NON REVERSING TYPE; IEC D SIZE; 18 AMPERE (UL), 32 AMPERE (IEC THERMAL CURRENT) CURRENT RATING; OPEN, DIN RAIL MOUNT ENCLOSURE TYPE; IEC CONSTRUCTION STANDARD; 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE; 1NO RIGHT MOUNT AUXILIARY CONTACT; 4 KW AT 220 V 3 PHASE, 7.5 KW AT 380/415/440 V 3 PHASE, 11 KW AT 500/550 V 3 PHASE, 5.5 KW AT 660 V 3 PHASE, 1 HP AT 115 V 1 PHASE, 3 HP AT 230 V 1 PHASE, 5 HP AT 208/240 V 3 PHASE, 10 HP AT 480 V 3 PHASE, 15 HP AT 600 V 3 PHASE POWER RATING/VOLTAGE; BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS; 1/3 PHASE; APPROVAL UL, CSA; NUMBER OF POLE 3; AE16 MODEL 0 $575.51 E
CUH AE16ENS0AC C-H AE16ENS0AC FRDM STR-IEC OP NON REVERSING TYPE; IEC E SIZE; 25 AMPERE (UL), 32 AMPERE (IEC THERMAL CURRENT) CURRENT RATING; OPEN, DIN RAIL MOUNT ENCLOSURE TYPE; IEC CONSTRUCTION STANDARD; 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE; 1NO RIGHT MOUNT AUXILIARY CONTACT; 5.5 KW AT 220 V 3 PHASE, 11 KW AT 380/415/440 V 3 PHASE, 15 KW AT 500/550 V 3 PHASE, 7.5 KW AT 660 V 3 PHASE, 2 HP AT 115 V 1 PHASE, 3 HP AT 230 V 1 PHASE, 5 HP AT 208 V 3 PHASE, 7-1/2 HP AT 240 V 3 PHASE, 15 HP AT 480 V 3 PHASE, 20 HP AT 600 V 3 PHASE POWER RATING/VOLTAGE; BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS; 1/3 PHASE; APPROVAL UL, CSA; NUMBER OF POLE 3; AE16 MODEL 0 $615.80 E
CUH AE16FN0BC C-H AE16FN0BC FRDM STR-IEC OPN NON REVERSING TYPE; IEC F SIZE; 32 AMPERE (UL, IEC THERMAL CURRENT) CURRENT RATING; OPEN, DIN RAIL MOUNT ENCLOSURE TYPE; IEC CONSTRUCTION STANDARD; 220 V AT 50 HZ, 240 V AT 60 HZ COIL VOLTAGE; 7.5 KW AT 220 V 3 PHASE, 10 KW AT 660 V 3 PHASE, 15 KW AT 380/415/440 V 3 PHASE, 18.5 KW AT 500/550 V 3 PHASE, 2 HP AT 115 V 1 PHASE, 5 HP AT 230 V 1 PHASE, 7-1/2 HP AT 208 V 3 PHASE, 10 HP AT 240 V 3 PHASE, 20 HP AT 480 V 3 PHASE, 25 HP AT 600 V 3 PHASE POWER RATING/VOLTAGE; BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS; 1/3 PHASE; APPROVAL UL, CSA; NUMBER OF POLE 3; AE16 MODEL 0 $616.62 E
CUH AE16FNS0AC C-H AE16FNS0AC FRDM STR-IEC OP NON REVERSING TYPE; IEC F SIZE; 32 AMPERE (UL/IEC THERMAL CURRENT) CURRENT RATING; OPEN, DIN RAIL MOUNT ENCLOSURE TYPE; IEC CONSTRUCTION STANDARD; 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE; 1NO RIGHT MOUNT AUXILIARY CONTACT; 7.5 KW AT 220 V 3 PHASE, 15 KW AT 380/415/440 V 3 PHASE, 18.5 KW AT 500/550 V 3 PHASE, 10 KW AT 660 V 3 PHASE, 2 HP AT 115 V 1 PHASE, 5 HP AT 230 V 1 PHASE, 7-1/2 HP AT 208 V 3 PHASE, 10 HP AT 240 V 3 PHASE, 20 HP AT 480 V 3 PHASE, 25 HP AT 600 V 3 PHASE POWER RATING/VOLTAGE; BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS; 1/3 PHASE; APPROVAL UL, CSA; NUMBER OF POLE 3; AE16 MODEL 0 $670.06 E
CUH AE16GN0AB C-H AE16GN0AB SIZE G STARTER NON REVERSING TYPE; IEC G SIZE; 37 AMPERE (UL), 50 AMPERE (IEC THERMAL CURRENT) CURRENT RATING; OPEN ENCLOSURE TYPE; IEC CONSTRUCTION STANDARD; 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE; 18.5 KW AT 380/415/440 V 3 PHASE, 22 KW AT 500/550 V 3 PHASE, 11 KW AT 660 V 3 PHASE, 3 HP AT 115 V 1 PHASE, 5 HP AT 230 V 1 PHASE, 7-1/2 HP AT 208 V 3 PHASE, 10 HP AT 240 V 3 PHASE, 25 HP AT 480 V 3 PHASE, 30 HP AT 600 V 3 PHASE POWER RATING/VOLTAGE; BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS; 1/3 PHASE; APPROVAL UL, CSA; NUMBER OF POLE 3; AE16 MODEL 0 $907.66 E
CUH AE16HN0AB C-H AE16HN0AB SIZE H STARTER NON REVERSING TYPE; IEC H SIZE; 44 AMPERE (UL), 60 AMPERE (IEC THERMAL CURRENT) CURRENT RATING; OPEN ENCLOSURE TYPE; IEC CONSTRUCTION STANDARD; 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE; 11 KW AT 220 V 3 PHASE, 22 KW AT 380/415/440 V 3 PHASE, 30 KW AT 500/550 V 3 PHASE, 15 KW AT 660 V 3 PHASE, 3 HP AT 115 V 1 PHASE, 7-1/2 HP AT 230 V 1 PHASE, 10 HP AT 208 V 3 PHASE, 15 HP AT 240 V 3 PHASE, 30 HP AT 480 V 3 PHASE, 40 HP AT 600 V 3 PHASE POWER RATING/VOLTAGE; BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS; 1/3 PHASE; APPROVAL UL, CSA; NUMBER OF POLE 3; AE16 MODEL 0 $957.81 E
CUH AE16JN0AB C-H AE16JN0AB SIZE J STARTER NON REVERSING TYPE; IEC J SIZE; 60 AMPERE (UL), 75 AMPERE (IEC THERMAL CURRENT) CURRENT RATING; OPEN ENCLOSURE TYPE; IEC CONSTRUCTION STANDARD; 110 VAC AT 50 HZ, 120 VAC AT 60 HZ COIL VOLTAGE; 15 KW AT 220 V 3 PHASE, 30 KW AT 380/415/440/500/550 V 3 PHASE, 18.5 KW AT 660 V 3 PHASE, 5 HP AT 115 V 1 PHASE, 10 HP AT 230 V 1 PHASE, 15 HP AT 208 V 3 PHASE, 20 HP AT 240 V 3 PHASE, 40 HP AT 480/600 V 3 PHASE POWER RATING/VOLTAGE; BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS; 1/3 PHASE; APPROVAL UL, CSA; NUMBER OF POLE 3; AE16 MODEL 0 $999.74 E